G720-Install-IG101 Installation Guide
Brocade
®
G720 Switch Hardware Installation Guide
•
mm
: Specifies the month. Valid values are 01 to 12.
•
dd
: Specifies the date. Valid values are 01 to 31.
•
hh
: Specifies the hour. Valid values are 00 to 23.
•
mm
: Specifies the minutes. Valid values are 00 to 59.
•
yy
: Specifies the year. Valid values are 00 to 37 and 70 to 99. Year values from 70 to 99 are interpreted as 1970 to
1999; year values from 00 to 37 are interpreted as 2000 to 2037.
device:admin> date
Thu Dec 22 14:05:10 UTC 2016
device:admin> date "1222150617"
Thu Dec 22 15:06:00 UTC 2017
Setting the Time Zone
The default time zone is Coordinated Universal Time (UTC). The time zone must be set only once because the value is
stored in nonvolatile memory. Use the following procedure to set the time zone.
1. Log on as admin.
2. Use the
tsTimeZone --interactive
command and follow the prompts, or enter the
tsTimeZone
-[
hour-
offset
,
minute-offset
] command as follows:
For Pacific Standard Time, enter
tsTimeZone -8,0
.
For Central Standard Time, enter
tsTimeZone -6,0
.
For Eastern Standard Time, enter
tsTimeZone -5,0
.
Table 8: tsTimeZone Command Parameter Selection for the U.S. Time Zones
Local Time
tsTimeZone Parameter (Difference from UTC)
Atlantic Standard
-4,0
Atlantic Daylight
-3,0
Eastern Standard
-5,0
Eastern Daylight
-4,0
Central Standard
-6,0
Central Daylight
-5,0
Mountain Standard
-7,0
Mountain Daylight
-6,0
Pacific Standard
-8,0
Pacific Daylight
-7,0
Alaskan Standard
-9,0
Alaskan Daylight
-8,0
Hawaiian Standard
-10,0
G720-Install-IG101
49
Broadcom
Содержание Brocade G720