Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 149 of 252
Status: 19.03.2021
4.13.2.1. List of input elements
The “Confirm”
button
Switch type
Description
Comment
1 (1 N.C.)
1 opening contact
Activation switch (standard)
2 (1 N.O.)
1 closing contact
Activation switch (standard)
3 (2 N.C.)
2 opening contacts
Activation switch with larger number of
requests
4 (2 time-monitoredd N.C.
’s)
2 opening contacts (time-monitored)
Activation switch (monitored)
Emergency stop
Switch type
Description
Comment
1 (1 N.C.)
1 opening contact
Emergency stop (standard)
3 (2 N.C.
’s
)
2 opening contacts
Energency stop with higher requirements
4 (2 N.C.
’s; time
-monitored) 2 opening contacts (time-monitored)
Emergency stop (monitored)
Door control
Switch type
Description
Comment
3 (2 N.C.)
2 opening contacts
Door monitorl with higher requirements
4 (2 N.C. time-monitored)
2 opening contacts (time-monitored)
Door monitor l (monitored)t
5 (1 N.O. 1 N.C.)
1 closing c 1 opening contact
Door monitor wit higher requirements
6 (1 N.O. 1 N.C.
time-monitored)
1 closing c 1 opening contact
(time-monitored)
Door monitor with higher requirements
7 (2 N.O. 2 N.C.)
2 closing contacts + 2 opening contacts
Door monitor with higher requirements
8 (2 N.O. 2 N.C.
time-monitored)
2 closing co 2 opening contacts
(time-monitored)
Door monitor (monitored)
9 (3 N.C.)
3 öffnende Kontakte
Door monitor with higher requirements
10 (3 N.C. time-monitored)
3 öffnende Kontakte zeitüberwacht
Door monitor (monitored)