Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 167 of 252
Status: 19.03.2021
cFLIP FLOP block
Set / reset switching element. This switching element saves the state in a tension-proof
way. After a POR, the state saved last is restored.
Functioning like RS FlipFlop. If both inputs are set to
“1”, the result is “0”
!
Figure 152 properties window
“
cFLIP FLOP
”
block
NOTICE:
After configuration data have been loaded on the safety block, the result is reset.
Logics 1-block
This module always provides the value “1”.
This function can be used for programming
static states in the function chart.
Example: assignation of an input that is not used to a direction-dependent SDI
Figure 153 properties window of logical 1- blocks