Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 151 of 252
Status: 19.03.2021
Operation mode switch
Switch type
Description
Comment
13 (N.C. N.O.)
Selection witch opening contact / closing contact
Selection switch (monitored)
14 (3 Phasen)
Selection switch 3 steps
Seklection switch (monitored)
15 (4 Phasen)
Information
If the status of the switch is changed, the SafePLC² programme warrants that the
outputs of the module are disabled. (Attention: standard 60204-Part1-Section 9.2.3).
Sensor
Switch type
Description
Comment
1 (1 N.C.)
1 opening contactt
Sensor input (standard)
2 (1 N.O.)
1 closing contacts
Sensor input (standard)
3 (2 N.C.)
2 opening contacts
Sensor input with thigher
requirements
4 (2 N.C. (time-monitored)
2 opening contacts (time-controlled)
Sensor input (time-controlled)
5 (1 N.O. 1 N.C.)
1 closing c 1 opening contact
(time-monitored)
Sensor input monitored