Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 220 of 252
Status: 19.03.2021
Figure 172 properties window of EOS function
Encoder -ID:
selection of the sensor that is connected eto encoder A (= 1) or to encoder B
(= 2).
Encoder type:
selection of encoder type.
Preset value:
preset value (set position) for the selected encoder.
NOTICE
:
At the most one EOS function can be used for the absolut encoder value. An operational activation
of the EOS function must be excluded. The function serves for maintenance and servicing. This
must be ensured by the selection of appropriate equipment. Appropriate equipment is e. g.
key-operated switches that are accessible only for qualified maintenance and service personnel.
Suitable organisational measures must be taken to grant the continuation of the physical position
on the axis according to the set position.
The calculated shift value must be saved in a voltage-protected manner.
For correct functioning, the ECS function must be activated while the EOS function is used.