Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 188 of 252
Status: 19.03.2021
-Sigmoidal
Quadratic calculation method for the stop distance in relation to the target position
Max. acceleration
Max. acceleration value within BX
Max. acceleration change
Value of maximum permissible acceleration change in BX when using the quadratic calculation
method.
Position tolerance
Max. permitted position deviations to target position
Reset
Selection of Reset.
Saving of the target position via the Teach-in
The Teach-in option can be used to save the target position in the SCU system without a
subsequent manual setting. To do this, the following steps are necessary:
By enabling the “
Teach-In
“
button, the input field
“Sollposition“
changes to
“
position range
“.
At the
same time, the input dialogue is enlarged by the SOS function.
The recording of a position with the Teach-in option can only be carried out during a standstill with
the SOS function being enabled and the SLP function being disabled.
For the recording of a position, the two signals “
Set
” and “
Quit
” are necessary.
These signals
appear as input connections of the function module, if the TeachÏn option is activated.
The Teach-In mode automatically activates the SOS function and checks the result of this function.
The missing triggering of the SOS function is a condition foran active Teach-In cycle.
The position is only recorded if the current position is situated within the determined position range.
The successfully recorded Teach-in position appears in the processs input image.
The Teach-in position is safely stored
–
also in case of acurrent interruption
The Teach-in position is reset after every configuration upload.
Curve type = Sigmoidal
[Curve type = quadratic]