Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 72 of 252
Status: 19.03.2021
Figure 48 information window
5. Compilation of the monitoring program
After programming has finished, the function plan is compiled and is converted into a
machine-readable format.
This process consists of the following steps
•
Check for open connectors in the logic plan
•
Check of the limit conditions for the monitoring functions
•
Check if the pulse numbers are correctly distributed via the cross-connections
•
Creation of a transferable OP programs for the module
6. Program transfer to the safety module by clicking on the device interface
After the dialogue window of the device interface has been opened, the software automatically
compiles the program. The program transmission process consists of:
•
Setting the COM-output or setting of the IP-address
•
Transmission of the automatic program meme.
•
Password entry. Corresponds to the serial number of the safety module (only if
TCP/IP-connection is used)
•
Test of the program meme in the module.
•
Creation of a validation report and validation of the configuration