Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 104 of 252
Status: 19.03.2021
The following selections are possible:
•
Encoder data
•
Speed sensor
•
Data of block SSX1
•
Data of block SSX2
•
Data of block SSX3
•
Data of block SSX4
•
SEL (time-based)
•
SLS filter
•
SCA filter
•
Sensor passport
•
Encoder positionn
•
Analogous filter
•
Analog adder
Depending on whether the encoder displays planned time values or position-dependent values, the
X-axis shows either the expiring control time or the measuring length configured in the encoder.
The Y values refer to the selected plan.
The plan cannot be changed during a current measuring.
Device:
selection of the device.
Axis:
If several identical functions are used, these can be selected and can be shown separately in
this selection. The values of these measuring data are shown for the relevant cursor positions.
By scaling the displayed diagram function, it is possible to adjust the Y
values in the individual curves via the slide bars 1 or 2.
Slide bar 1:
changes the visible range of the Y values in the diagram.
Slide bar 2:
changes the displayed maximum range oft he Y values in
the diagram.
Figure 84 Scaling the diagram
via the slide bars