Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 115 of 252
Status: 19.03.2021
4.9. Device interface
The device interface is displayed in the device window. This window contains advanced
communication options, e. g., programme transmission, diagnosis and range monitoring by
connected SCU devices. If the device interface is opened, the programme automatically starts the
compilation. The window contains the instruments of the device interface.
Symbols in the device interface:
Figure 87 Symbols in the device interface
–
not connected
Figure 88 Symbols
–
connected
Connect:
starts the connection with the SCU system.
Disconnect:
disconnects an active connection
Start:
Starts the programme sequence in the
“Connected” mode
.
Stop:
Stops the programme sequence in the
“Connected”
Verify:
Compares the application of the SafePLC² to that on the SCU system by means of the
CRC.
Connection Settings:
Opens the document properties with the connection settings. To create a
connection with an SCU system, the transmission parameters must be set accordingly.
Connection:
Sends or reads the current configuration to/ into the file. This function is disabled if
the diagnostics window or the range window is open.
Send configuration:
Transmits the
configuration of the function block diagram to the SCU system.
This is only possible in the “Stop” mode.
Lock configuration:
After every configuration data transfer to an SCU system, these data are
marked “Not validated “
. The basis group signals this by the status LED flashin yellow. Wigh the
“Disable configuration” command access to the configuration data can be disabled in the basis
block. This is indicated by the status LED flashing green.