Parameter set 3
Parameters
Controller BUS 6 T
89
Baumüller Nürnberg GmbH
5.94017.06
7.7.3 Speed controller
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
speed controller
12388
speed controller gain
1.00 ... 400.00
12389
speed controller integral-action time
4.00 ... 655.00
ms
12497
lower adaptation limit for speed
controller
0 ... 0
rpm
0
12498
upper adaptation limit for speed
controller
10.0000 ... 1000.0000
rpm
200
12499
proportional gain adaptation
100.0 ... 1000.0
%
12500
integral-action time adaptation
1.0 ... 100.0
%
45217
set velocity window KI counter
N_I_component)
1.0000 ... 600.0000
rpm
45218
delete velocity window N_I_component
1.0000 ... 600.0000
rpm
45220
actual speed value time constant
0.0 ... 60.0
ms
0
7.7.4 Messages - monitoring
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
messages - monitoring
12412
speed threshold n
min
6.0000 ... 600.0000
rpm
100
12445
velocity window
6.0000 ... 600.0000
rpm
120
12413
velocity threshold n
x
6.0000 ... 1200.0000
rpm
100
45117
velocity threshold n
max
1200.0000 ... 12000.0000
rpm
45119
maximum intermediate circuit voltage
threshold
20 ... 800
V
12414
torque threshold M
dx
10.0 ... 100.0
%
90
45118
response time Pzkx (M
dx
)
0.100 ... 30.000
s
0.5
Parameter description
Parameter description see parameter set 0.
Содержание BUS 6-T Series
Страница 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 16: ...Type code Technical data 10 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 2 3 Type code ...
Страница 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 26: ...Installation Terminal Diagram 20 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 5 4 Terminal diagram I ...
Страница 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 45: ...Initial commissioning Commissioning Controller BUS 6 T 39 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 46: ...Commissioning Initial commissioning 40 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 47: ...Initial commissioning Commissioning Controller BUS 6 T 41 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 49: ...Main spindle area Commissioning Controller BUS 6 T 43 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 56: ...Parameters Basic settings 50 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 7 2 Basic settings ...
Страница 79: ...Parameter set 0 Parameters Controller BUS 6 T 73 Baumüller Nürnberg GmbH 5 94017 06 7 4 Parameter set 0 ...
Страница 85: ...Parameter set 0 Parameters Controller BUS 6 T 79 Baumüller Nürnberg GmbH 5 94017 06 7 4 3 Speed controller ...
Страница 106: ...Maintenance Status messages 100 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 8 2 Status messages ...