Parameters
Display and measuring parameters
66
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
7.3.3 Characteristic curve of magnetisation (asynchronous machines only)
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
characteristic curve of magnetisation
32872
N_1
0.0000 ... 10000.0000
rpm
1500
32873
N_2
0.0000 ... 10000.0000
rpm
1700
32874
N_3
0.0000 ... 10000.0000
rpm
2000
32875
N_4
0.0000 ... 10000.0000
rpm
2500
32876
N_5
0.0000 ... 10000.0000
rpm
3000
32877
N_6
0.0000 ... 10000.0000
rpm
3750
32878
N_7
0.0000 ... 10000.0000
rpm
4500
32879
N_8
0.0000 ... 10000.0000
rpm
6000
32880
N_9
0.0000 ... 10000.0000
rpm
7200
32881
N_10
0.0000 ... 10000.0000
rpm
9600
32882
N_11
0.0000 ... 10000.0000
rpm
12000
32883
N_12
0.0000 ... 14400.0000
rpm
14400
characteristic curve of magnetisation
32884
P_1
0.00 ... 140.00
%
100.00
32885
P_2
0.00 ... 100.00
%
83.00
32886
P_3
0.00 ... 100.00
%
70.00
32887
P_4
0.00 ... 100.00
%
54.50
32888
P_5
0.00 ... 100.00
%
46.00
32889
P_6
0.00 ... 100.00
%
38.00
32890
P_7
0.00 ... 100.00
%
31.00
32891
P_8
0.00 ... 100.00
%
24.00
32892
P_9
0.00 ... 100.00
%
20.00
32893
P_10
0.00 ... 100.00
%
14.00
32894
P_11
0.00 ... 100.00
%
12.00
32895
P_12
0.00 ... 100.00
%
10.00
Parameter description
N_1
bis
N_1 < N_2 < ... < N_12
N_12
P_1
bis
P_1 > P_2 > ... < P_12
P_12
The respective speed is set under N_1 to N_12, the appropriate factor for the description of
the characteristic curve of magnetisation is set under P_1 to P_12.
Содержание BUS 6-T Series
Страница 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 16: ...Type code Technical data 10 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 2 3 Type code ...
Страница 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 26: ...Installation Terminal Diagram 20 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 5 4 Terminal diagram I ...
Страница 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 45: ...Initial commissioning Commissioning Controller BUS 6 T 39 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 46: ...Commissioning Initial commissioning 40 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 47: ...Initial commissioning Commissioning Controller BUS 6 T 41 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 49: ...Main spindle area Commissioning Controller BUS 6 T 43 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 56: ...Parameters Basic settings 50 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 7 2 Basic settings ...
Страница 79: ...Parameter set 0 Parameters Controller BUS 6 T 73 Baumüller Nürnberg GmbH 5 94017 06 7 4 Parameter set 0 ...
Страница 85: ...Parameter set 0 Parameters Controller BUS 6 T 79 Baumüller Nürnberg GmbH 5 94017 06 7 4 3 Speed controller ...
Страница 106: ...Maintenance Status messages 100 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 8 2 Status messages ...