Display and measuring parameters
Parameters
Controller BUS 6 T
71
Baumüller Nürnberg GmbH
5.94017.06
7.3.6 Display of controller parameters
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
display of controller parameters
32864
ramp function generator output
-2147483648 ... +2147483647
32865
rounding generator output
-2147483648 ... +2147483647
32863
set speed value
-2147483648 ... +2147483647
32856
speed controller output
-2147483648 ... +2147483647
32870
counter delete N_I_portion
0 ... 65535
32848
set active current
-2147483648 ... +2147483647
32846
actual torque value
-32768 ... +32767
32854
torque controller output
-32768 ... +32767
32896
set flux value
-32768 ... +32767
32847
actual flux value
-32768 ... +32767
32855
flux controller output
-32768 ... +32767
32869
actual speed value
-12000.0000 ... 12000.0000
rpm
32776
actual slip frequency value
-1000.0000 ... +1000.0000
Hz
32859
P gain speed controller
-2147483648 ... +2147483647
32860
integral action time speed controller
-2147483648 ... +2147483647
32850
P gain torque controller
-2147483648 ... +2147483647
32851
integral action time torque controller
-2147483648 ... +2147483647
32852
P gain flux controller
-2147483648 ... +2147483647
32853
integral action time flux controller
-2147483648 ... +2147483647
32861
real torque limitation positive
-2147483648 ... +2147483647
32862
real torque limitation negative
-2147483648 ... +2147483647
32842
cos(
ω
t)
-32768 ... +32767
32843
sin(
ω
t)
-32768 ... +32767
32844
IU
actual value
-512 ... +511
32845
IV
actual value
-512 ... +511
32866
set torque value by torque control
-2147483648 ... +2147483647
51
actual position value
-4×360.0000 ... +4×360.0000
32898
hardware verion
0000 ... 7FFF
32899
software version
0000 ... 7FFF
32785
boot initialisation error
32786
error bar of I/O component boot
Содержание BUS 6-T Series
Страница 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 16: ...Type code Technical data 10 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 2 3 Type code ...
Страница 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 26: ...Installation Terminal Diagram 20 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 5 4 Terminal diagram I ...
Страница 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 45: ...Initial commissioning Commissioning Controller BUS 6 T 39 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 46: ...Commissioning Initial commissioning 40 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 47: ...Initial commissioning Commissioning Controller BUS 6 T 41 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 49: ...Main spindle area Commissioning Controller BUS 6 T 43 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 56: ...Parameters Basic settings 50 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 7 2 Basic settings ...
Страница 79: ...Parameter set 0 Parameters Controller BUS 6 T 73 Baumüller Nürnberg GmbH 5 94017 06 7 4 Parameter set 0 ...
Страница 85: ...Parameter set 0 Parameters Controller BUS 6 T 79 Baumüller Nürnberg GmbH 5 94017 06 7 4 3 Speed controller ...
Страница 106: ...Maintenance Status messages 100 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 8 2 Status messages ...