Set value adaptation
Parameters
Controller BUS 6 T
93
Baumüller Nürnberg GmbH
5.94017.06
7.9 Set value adaptation
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
set value adaptation
32922
n
set
main spindle offset
- 100.0000 ... 100.0000
rpm
32923
n
set
C axis offset
- 100.0000 ... + 100.0000
rpm
32924
M
set
offset
- 2 ... + 2
%
0
32925
n
set
-max MSP
- 100.0000 ... 12000.0000
rpm
32926
M limitation analog
0 ... 2
0
Parameter description:
n
set
main spindle offset
n
set
C axis offset
M
set
offset
With analog set value input these parameters serve for offset correction.
n
set
max MSP
This parameter sets the maximum speed by
±
10 V at X2:1/2.
±
10 V
⇔
±
n
soll
max MSP (rpm)
min. value:
100 rpm
max. value:
n
max
(ID no. 113) + 200 rpm
M limitation analog
This parameter sets the torque threshold (ID no. 32818 = 0).
Value
Meaning
0
symmetric limitation of both torque directions
X2:7=+10 V or -10 V
torque limitation positive = +100 %
torque limitation negative = -100 %
torque limitation bipolar = 100 %
1
not symmetric
X2:7=+10 V
torque limitation positive = +100 %
torque limitation negative = 0 %
torque limitation bipolar = 100 %
X2:7=-10 V
torque limitation positive = 0 %
torque limitation negative = -100 %
torque limitation bipolar = 100 %
2
torque limitations the same as set digital value
Содержание BUS 6-T Series
Страница 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 16: ...Type code Technical data 10 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 2 3 Type code ...
Страница 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 26: ...Installation Terminal Diagram 20 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 5 4 Terminal diagram I ...
Страница 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 45: ...Initial commissioning Commissioning Controller BUS 6 T 39 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 46: ...Commissioning Initial commissioning 40 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 47: ...Initial commissioning Commissioning Controller BUS 6 T 41 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 49: ...Main spindle area Commissioning Controller BUS 6 T 43 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 56: ...Parameters Basic settings 50 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 7 2 Basic settings ...
Страница 79: ...Parameter set 0 Parameters Controller BUS 6 T 73 Baumüller Nürnberg GmbH 5 94017 06 7 4 Parameter set 0 ...
Страница 85: ...Parameter set 0 Parameters Controller BUS 6 T 79 Baumüller Nürnberg GmbH 5 94017 06 7 4 3 Speed controller ...
Страница 106: ...Maintenance Status messages 100 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 8 2 Status messages ...