Status messages
Maintenance
Controller BUS 6 T
103
Baumüller Nürnberg GmbH
5.94017.06
BUS operating error
An operating error of the servo unit leads to pulse inhibit (PI) or controller inhibit (CI).
Bit no.
Meaning
0
1: power unit ready for use (PI)
1
1: communication not enabled (PI)
2
1: power unit error (PI)
3
1: auxiliary voltage failure (PI)
4
1: excess current error (PI)
5
1: fault current (PI)
6
1: reference voltage error (PI)
7
1: overvoltage error (PI)
8
1: transistor error V1l BUS (PI)
9
1: transistor error V1u BUS (PI)
10
1: transistor error V2l BUS (PI)
11
1: transistor error V2u BUS (PI)
12
1: transistor error V3l BUS (PI)
13
1: transistor error V3u BUS (PI)
14
1: BUG ready for use (PI)
15
1: actual speed > limit speed (CI)
BUS hardware error
According to the error type a hardware error of the servo unit either leads to pulse inhibit
(PI) or to controller inhibit (CI).
Bit no.
Meaning
0
1: error of internal RAM
1
1: error of external RAM
2
1: memory submodule EPROM not available
3
1: memory submodule EEPROM faulty
4
1: memory submodule EEPROM not available
5
1: timeout at upper A/D converter (CI)
6
1: timeout at lower A/D converter (CI)
7
1: offset error at upper A/D converter (CI)
8
1: offset error at lower A/D converter (CI)
9
1: error during power unit recognition (PI)
10
1: error during motor recognition (PI)
11
1: encoder module 1 not available (PI)
12
1: break of amplifier temperature sensor (CI)
13
1: break of circuitry housing temperature sensor (CI)
14
1: break of motor temperature sensor (CI)
15
1: initialisation error of I/O components (PI)
Содержание BUS 6-T Series
Страница 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 16: ...Type code Technical data 10 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 2 3 Type code ...
Страница 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 26: ...Installation Terminal Diagram 20 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 5 4 Terminal diagram I ...
Страница 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 45: ...Initial commissioning Commissioning Controller BUS 6 T 39 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 46: ...Commissioning Initial commissioning 40 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 47: ...Initial commissioning Commissioning Controller BUS 6 T 41 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 49: ...Main spindle area Commissioning Controller BUS 6 T 43 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 56: ...Parameters Basic settings 50 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 7 2 Basic settings ...
Страница 79: ...Parameter set 0 Parameters Controller BUS 6 T 73 Baumüller Nürnberg GmbH 5 94017 06 7 4 Parameter set 0 ...
Страница 85: ...Parameter set 0 Parameters Controller BUS 6 T 79 Baumüller Nürnberg GmbH 5 94017 06 7 4 3 Speed controller ...
Страница 106: ...Maintenance Status messages 100 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 8 2 Status messages ...