Basic settings
Parameters
Controller BUS 6 T
57
Baumüller Nürnberg GmbH
5.94017.06
7.2.2 Motor-specific values (menu pages 3 - 5)
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
menu page 3
motor-specific values
32897
temperature modell
0 ... 1
1
32794
application speed for
for motor nominal power
500.0000 ... 12000.0000
rpm
32810
rotor time constant
100.0 ... 1000.0
ms
32814
set magnetising current value
0.0 ... 500.0
A
32815
magnetising current limitation
0.0 ... 500.0
A
32804
set active current value
0.0 ... 500.0
A
32805
active current limitation
0.0 ... 500.0
A
32801
time constant of actual torque value
1.000 ... 10.000
ms
32816
set apparent current value
0.0 ... 750.0
A
32817
apparent current limitation
0.0 ... 900.0
A
32933
time constant set torque value
0.0000 ... 10.000
ms
2
menu page 4
motor-specific values
32802
torque controller gain
0.10 ... 3.00
32803
torque controller integral-action time
1.000 ... 6.000
ms
32811
flux controller gain
1.00 ... 10.00
32813
flux controller integral-action time
1.000 ... 30.000
ms
32835
upper adaption limitation for current
controller
0000.0000 ... 12000.0000
min-1
32927
I controller phase compensation stat.
0.00 ... 3.00
32928
I controller phase compensation dyn.
0 ... 256
32812
adaption flux controller gain
100.0 ... 1000.0
%
menu page 5
motor-specific values
32798
torque limitation for f<10Hz
0 ... 1
32799
application speed for torque limitation
50.0000 ... 500.0000
rpm
32800
maximum torque at rest
50.0 ... 100.0
%
32806
torque limitation for high speeds
0 ... 1
32807
application speed for torque limitation
1500.0000 ... 120000.0000
rpm
32808
torque at maximum speed
10.0 ... 100.0
%
32795
generator torque limitation
0 ... 1
32796
generator torque limitation 1
80.0 ... 100.0
%
32797
generator torque limitation 2
10.0 ... 79.0
%
Содержание BUS 6-T Series
Страница 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 16: ...Type code Technical data 10 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 2 3 Type code ...
Страница 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 26: ...Installation Terminal Diagram 20 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 5 4 Terminal diagram I ...
Страница 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Страница 45: ...Initial commissioning Commissioning Controller BUS 6 T 39 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 46: ...Commissioning Initial commissioning 40 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 47: ...Initial commissioning Commissioning Controller BUS 6 T 41 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 49: ...Main spindle area Commissioning Controller BUS 6 T 43 Baumüller Nürnberg GmbH 5 94017 06 PC unit ...
Страница 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...
Страница 56: ...Parameters Basic settings 50 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 7 2 Basic settings ...
Страница 79: ...Parameter set 0 Parameters Controller BUS 6 T 73 Baumüller Nürnberg GmbH 5 94017 06 7 4 Parameter set 0 ...
Страница 85: ...Parameter set 0 Parameters Controller BUS 6 T 79 Baumüller Nürnberg GmbH 5 94017 06 7 4 3 Speed controller ...
Страница 106: ...Maintenance Status messages 100 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH 8 2 Status messages ...