Installation • Connection examples
168
Panel PC 800 User's Manual V1.30
5.5 One AP900 and one AP800 via onboard SDL
An Automation Panel 900 and an Automation Panel 800 are connected to the integrated SDL interface (onboard)
via SDL.
USB is supported up to a maximum distance (segment 1 + segment 2) of 30 m on the two displays. Past a distance
of 30 m, USB is only available on the first display (front and back) up to 40 m. USB devices can only be connected
directly to the Automation Panel 900 or extension keyboard (without a hub).
USB OK
SDL segment 1
Max. 40 m
AP900
SDVO-B
Internal device number on the PPC
SDL segment 2
Max. 40 m
Independent of segment length
Depends on segment length
Panel PC 800
USB
possible
AP800
Monitor/Panel
Connection
Figure 78: One AP900 and one AP800 via onboard SDL
5.5.1 Base system requirements
The following table lists the possible PPC800 system unit and CPU board combinations necessary to implement
the configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this
is also indicated (e.g. when connecting a non-B&R Automation Panel 800 / 900 device).
With system unit
CPU board
5PC820.1505-00
5PC820.1906-00
Limitation
Resolution
5PC800.B945-00
5PC800.B945-10
✓
✓
Max. UXGA
5PC800.B945-01
5PC800.B945-11
✓
✓
Max. UXGA
5PC800.B945-02
5PC800.B945-12
✓
✓
Max. UXGA
5PC800.B945-03
5PC800.B945-13
✓
✓
Max. UXGA
5PC800.B945-04
5PC800.B945-14
✓
✓
Max. UXGA
5PC800.B945-05
✓
✓
Max. UXGA
Table 133: Possible system unit and CPU board combinations
5.5.2 Link modules
Information:
A corresponding Link module must be selected for each device used.
Model number
Description
Note
5DLSDL.1000-01
Automation Panel Link SDL transceiver
Connections for SDL In and SDL Out; transmission of display, touch screen, USB 1.1, matrix key and
service data; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Table 134: Link modules
5.5.3 Cables