Software • B&R Automation Device Interface (ADI) - Control Center
Chapter 4 Software
Panel PC 800 User's Manual V1.30
255
The displayed values are updated automatically.
Information:
The status "Reversed battery polarity" is only displayed if using UPS firmware version 1.08 or higher.
With UPS firmware versions 1.07 and older, switching between battery operation and normal operation
can lead to a communication error.
3. Select "UPS monitor" to display UPS status changes since the last time the system or UPS driver was started.
Figure 137: ADI Control Center - UPS monitor
The window is updated automatically when the status changes.
To remove a status from the list, click on
Clear
.
Information:
The current status of the UPS is also displayed on the UPS page in the power options when the UPS
service is started in the Windows Control Panel.
Information:
In a German version of Windows XP Professional the battery status is shown as "Low" in the power
options even if the battery is OK (Windows error). In an English version, three battery status levels are
displayed: unknown, OK and replace. A low battery status is never displayed.
11.4.3 Changing UPS battery settings
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.
3. Under
Battery settings
, click on
Edit
. This opens the "Open" dialog box.
4. Select and
open
the file containing the battery settings.