Installation • Connection examples
170
Panel PC 800 User's Manual V1.30
5.6 Four Automation Panel 900 systems via onboard SDL
An Automation Panel 900 is connected to the integrated SDL interface (onboard) via an SDL cable. Up to three
other Automation Panels of the same type are connected to this Automation Panel and operated via SDL. All four
of the panels show the same content (display clone).
USB is supported up to a maximum distance (SDL segment 1 + SDL segment 2) of 30 m on the first two panels
(front and back). Past a distance of 30 m, USB is only available for the first panel (front and back). USB devices
can only be connected directly to the Automation Panel (i.e. without a hub).
Panel PC 800
SDL segment 1
Max. 40 m
No USB
possible
USB OK
SDVO-B
Internal device number on the PPC
SDL segment 2
Max. 40 m
SD
L
se
gm
en
t 3
M
ax
. 4
0
m
SDL segment 4
Max. 40 m
No USB
possible
USB
possible
Independent of segment length
Depends on segment length
Monitor/Panel
Connection
Figure 79: Four Automation Panel 900 systems via onboard SDL
5.6.1 Base system requirements
The following table lists the possible PPC800 system unit and CPU board combinations necessary to implement
the configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this
is also indicated (e.g. when connecting a non-B&R Automation Panel 800 / 900 device).
With system unit
CPU board
5PC820.1505-00
5PC820.1906-00
Limitation
Resolution
5PC800.B945-00
5PC800.B945-10
✓
✓
Max. UXGA
5PC800.B945-01
5PC800.B945-11
✓
✓
Max. UXGA
5PC800.B945-02
5PC800.B945-12
✓
✓
Max. UXGA
5PC800.B945-03
5PC800.B945-13
✓
✓
Max. UXGA
5PC800.B945-04
5PC800.B945-14
✓
✓
Max. UXGA
5PC800.B945-05
✓
✓
Max. UXGA
Table 135: Possible system unit and CPU board combinations
5.6.2 Link modules
Information:
A corresponding Link module must be selected for each device used.
Model number
Description
Note
5DLSDL.1000-00
Automation Panel Link SDL receiver
Connection for SDL In; transmission of display, touch screen, USB 1.1, matrix key and service data; 24
VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
5DLSDL.1000-01
Automation Panel Link SDL transceiver
Connections for SDL In and SDL Out; transmission of display, touch screen, USB 1.1, matrix key and
service data; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Table 136: Link modules
5.6.3 Cables
Select an Automation Panel 900 cable from the following table.