Technical data • Individual components
88
Panel PC 800 User's Manual V1.30
Product ID
5AC801.HDDI-02
Environmental conditions
Temperature
3)
Operation
-15 to 80°C
24-hour operation
4)
-15 to 80°C
Storage
-40 to 95°C
Transport
-40 to 95°C
Relative humidity
5)
Operation
8 to 90%, non-condensing
6)
Storage
5 to 95%, non-condensing
7)
Transport
5 to 95%, non-condensing
7)
Vibration
Operation
5 to 500 Hz: 1 g; no unrecoverable errors
Storage
5 to 500 Hz: 5 g, no damage
Transport
5 to 500 Hz: 5 g, no damage
Shock
Operation
325 g and 2 ms duration; no unrecoverable errors
Storage
900 g, 1 ms; no damage
120 g, 11 ms; no damage
Transport
900 g, 1 ms; no damage
120 g, 11 ms; no damage
Altitude
Operation
-300 to 3000 m
Storage
-300 to 12192 m
Mechanical characteristics
Installation
Fixed
8)
Dimensions
Width
13 mm
Height
98 mm
Depth
105 mm
Weight
135 g
Manufacturer information
Manufacturer
Fujitsu
Manufacturer's product ID
MHY2160BH-ESW
Table 67: 5AC801.HDDI-02 - Technical data
1)
Yes, although applies only if all components installed within the complete system have this certification
2)
With 8760 POH (power-on hours) per year and 70°C surface temperature.
3)
Standard operation refers to 333 POH (power-on hours) per month.
4)
24-hour operation refers to 732 POH (power-on hours) per month.
5)
Humidity gradient: Maximum 15% per hour.
6)
Maximum humidity at 29°C.
7)
Maximum humidity at 40°C.
8)
Slide-in compact installation.
3.9.2.4 Temperature humidity diagram
90
Temperature [°C]
R
el
at
iv
e
hu
m
id
ity
[%
R
H
] (
no
n-
co
nd
en
si
ng
)
Operation
Storage
Transport
Figure 31: 5AC801.HDDI-02 - Temperature humidity diagram