Technical data • Individual components
136
Panel PC 800 User's Manual V1.30
5)
Humidity gradient: Maximum 30% per hour.
6)
Operation in areas prone to vibration and shock can affect performance negatively (reduction of transfer rate).
7)
Installed in PCI slot.
3.9.22.4 Temperature humidity diagram
Temperature [°C]
R
el
at
iv
e
hu
m
id
ity
[%
R
H
] (
no
n-
co
nd
en
si
ng
)
Operation
Storage
Transport
Figure 58: 5ACPCI.RAIC-05 - Temperature humidity diagram
3.9.22.5 Driver support
Special drivers are necessary for operating the PCI SATA RAID controller. Drivers for supported and approved
operating systems are available in the Downloads section of the B&R website (
.NET-based SATA Raid™ serial ATA RAID management software can also be found on the B&R website.
Information:
Required drivers can only be downloaded from the B&R website, not from manufacturer websites.
3.9.22.6 Configuration
For information about configuring a SATA RAID set, see 3 "Installation", section 8 "Configuring a SATA RAID set"
3.9.22.7 Replacing a HDD
A hard drive can be easily replaced in the event of an error when using the RAID1 (mirroring) configuration without
having to reinstall the system. The 250 GB 5MMHDD.0250-00 SATA HDD is available as a replacement hard disk.
For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set"