Installation • Connection examples
166
Panel PC 800 User's Manual V1.30
5.4 One Automation Panel 800 system via onboard SDL
An Automation Panel 800 is connected to the integrated SDL interface (onboard) via an SDL cable. USB devices
can only be connected directly to the extension keyboard (without a hub).
Panel PC 800
Monitor/Panel
Connection
SDL segment 1
max. 40 m
SDVO-B
Internal device number on the PPC
AP800
USB OK
Independent of segment length
Figure 77: One Automation Panel 800 system via onboard SDL
5.4.1 Base system requirements
The following table lists the possible PPC800 system unit and CPU board combinations necessary to implement
the configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this
is also indicated (e.g. when connecting a non-B&R Automation Panel 800 / 900 device).
With system unit
CPU board
5PC820.1505-00
5PC820.1906-00
Limitation
Resolution
5PC800.B945-00
5PC800.B945-10
✓
✓
Max. UXGA
5PC800.B945-01
5PC800.B945-11
✓
✓
Max. UXGA
5PC800.B945-02
5PC800.B945-12
✓
✓
Max. UXGA
5PC800.B945-03
5PC800.B945-13
✓
✓
Max. UXGA
5PC800.B945-04
5PC800.B945-14
✓
✓
Max. UXGA
5PC800.B945-05
✓
✓
Max. UXGA
Table 130: Possible system unit and CPU board combinations
5.4.2 Cables
Select an Automation Panel 800 SDL cable from the following table.
Model number
Description
Length
5CASDL.0018-20
SDL flex cable for the Automation Panel 800, 1.8 m
1.8 m ±20 mm
5CASDL.0050-20
SDL flex cable for the Automation Panel 800, 5 m
5 m ±45 mm
5CASDL.0100-20
SDL flex cable for the Automation Panel 800, 10 m
10 m ±90 mm
5CASDL.0150-20
SDL flex cable for the Automation Panel 800, 15 m
15 m ±135 mm
5CASDL.0200-20
SDL flex cable for the Automation Panel 800, 20 m
20 m ±180 mm
5CASDL.0250-20
SDL flex cable for the Automation Panel 800, 25 m
25 m ±230 mm
5CASDL.0300-30
SDL flex cable with extender for the Automation Panel 800, 30 m
30 m ±280 mm
5CASDL.0400-30
SDL flex cable with extender for the Automation Panel 800, 40 m
40 m ±380 mm
Table 131: Cables for SDL configurations
Information:
Detailed technical data about cables can be found in the Automation Panel 800 user's manual. This
can be downloaded as a PDF file from the B&R website at
5.4.2.1 Cable lengths and resolutions for SDL transmission
The following table lists the relationship between segment lengths and maximum resolution depending on the SDL
cable being used: