Technical data • Individual components
Chapter 2
Technical data
Panel PC 800 User's Manual V1.30
143
Product ID
5MMHDD.0500-00
Data transfer rate
Internal
Max. 147 MB/s
To/From host
Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II)
Positioning time
Nominal (read only)
11 ms
Maximum (read only)
21 ms
Environmental conditions
Temperature
3)
Operation
4)
0 to 60°C
24-hour operation
5)
0 to 60°C
Storage
-40 to 70°C
Transport
-40 to 70°C
Relative humidity
6)
Operation
5 to 95%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Vibration
Operation (continuous)
5 to 500 Hz: 0.25 g; no unrecoverable errors
Operation (occasional)
5 to 500 Hz: 0.5 g; no unrecoverable errors
Storage
10 to 500 Hz: 5 g; no unrecoverable errors
Transport
10 to 500 Hz: 5 g; no unrecoverable errors
Shock
Operation
400 g and 2 ms duration; no unrecoverable errors
Storage
1000 g and 2 ms duration; no unrecoverable errors
Transport
1000 g and 2 ms duration; no unrecoverable errors
Altitude
Operation
-305 to 3048 m
Storage
-305 to 12192 m
Mechanical characteristics
Dimensions
Width
7 mm
Height
69 mm
Depth
100 mm
Weight
100 g
Manufacturer information
Manufacturer
Western Digital
Manufacturer's product ID
WD5000LUCT
Table 113: 5MMHDD.0500-00 - Technical data
1)
Yes, although applies only if all components installed within the complete system have this certification
2)
With 8760 POH (power-on hours) per year and 25°C surface temperature.
3)
Temperature values at an elevation of 305 meters. The temperature specification must be reduced linearly by 1°C every 305 meters. The temperature
increase and decrease can be a maximum of 20°C per hour.
4)
Standard operation refers to 333 POH (power-on hours) per month.
5)
24-hour operation refers to 732 POH (power-on hours) per month.
6)
Humidity gradient: Maximum 20% per hour.
3.9.25.4 Temperature humidity diagram
Temperature [°C]
R
el
at
iv
e
hu
m
id
ity
[%
R
H
] (
no
n-
co
nd
en
si
ng
)
Operation
Storage
Transport
Figure 62: 5MMHDD.0500-00 - Temperature humidity diagram