Model number
Description
Length
5CASDL.0100-03
SDL flex cable, 10 m
10 m ±90 mm
5CASDL.0150-03
SDL flex cable, 15 m
15 m ±135 mm
5CASDL.0200-03
SDL flex cable, 20 m
20 m ±180 mm
5CASDL.0250-03
SDL flex cable, 25 m
25 m ±225 mm
5CASDL.0300-03
SDL flex cable, 30 m
30 m ±270 mm
5CASDL.0300-13
SDL flex cable with extender, 30 m
30 m ±280 mm
5CASDL.0400-13
SDL flex cable with extender, 40 m
40 m ±380 mm
5CASDL.0430-13
SDL flex cable with extender, 43 m
43 m ±410 mm
5CASDL.0018-01
SDL cable with 45° male connector, 1.8 m
1.8 m ±30 mm
5CASDL.0050-01
SDL cable with 45° male connector, 5 m
5 m ±50 mm
5CASDL.0100-01
SDL cable with 45° male connector, 10 m
10 m ±100 mm
5CASDL.0150-01
SDL cable with 45° male connector, 15 m
15 m ±100 mm
Table 128: Cables for SDL configurations
Information:
Detailed technical data about cables can be found in the Automation Panel 900 user's manual. This
can be downloaded as a PDF file from the B&R website at
5.3.3.1 Cable lengths and resolutions for SDL transmission
The following table lists the relationship between segment lengths and maximum resolution depending on the SDL
cable being used:
Resolution
SDL cable
Segment length [m]
VGA
640 x 480
SVGA
800 x 600
XGA
1024 x 768
SXGA
1280 x 1024
UXGA
1600 x 1200
FHD
1920 x 1080
1.8
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
10
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
15
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
-
-
-
-
-
5CASDL.0150-03
20
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
-
-
-
5CASDL.0200-03
25
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
-
-
-
-
-
-
30
5CASDL.0300-00
5CASDL.0300-03
5CASDL.0300-00
5CASDL.0300-03
-
5CASDL.0300-13
-
5CASDL.0300-13
-
-
-
5CASDL.0300-13
40
5CASDL.0400-13
5CASDL.0400-13
5CASDL.0400-13
5CASDL.0400-13
-
5CASDL.0400-13
Table 129: Cable lengths and resolutions for SDL transmission
5.3.4 Settings in BIOS
No special BIOS settings are necessary for operation.
For detailed information, see the user's manual for the B&R Industrial PC being used.
Touch screen functionality
COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel
interface ("Advanced - Baseboard/Panel features - Legacy devices").