Installation • Connection examples
162
Panel PC 800 User's Manual V1.30
5.2 One Automation Panel 900 system via onboard DVI
An Automation Panel 900 with max. SXGA resolution is connected to the integrated DVI interface (onboard). As
an alternative, an office TFT with a DVI interface or analog monitor (using adapter 5AC900.1000-00) can also be
used. A separate cable is used for both the touch screen and USB data. If USB devices are to be operated on
the Automation Panel 900, the maximum distance is 5 meters. USB devices can only be connected directly to the
Automation Panel (i.e. without a hub).
Panel PC 800
RS232 cables
DVI cables
USB cables
5 meter segment length (with USB)
Max. 10 meters (without USB)
AP900
USB up to
5 m OK
Monitor/Panel
Connection
Figure 75: One Automation Panel 900 via DVI
5.2.1 Base system requirements
The following table lists the possible PPC800 system unit and CPU board combinations necessary to implement
the configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this
is also indicated (e.g. when connecting a non-B&R Automation Panel 900 device).
With system unit
CPU board
5PC820.1505-00
5PC820.1906-00
Limitation
Resolution
5PC800.B945-00
5PC800.B945-10
✓
✓
Max. SXGA
5PC800.B945-01
5PC800.B945-11
✓
✓
Max. SXGA
5PC800.B945-02
5PC800.B945-12
✓
✓
Max. SXGA
5PC800.B945-03
5PC800.B945-13
✓
✓
Max. SXGA
5PC800.B945-04
5PC800.B945-14
✓
✓
Max. SXGA
5PC800.B945-05
✓
✓
Max. SXGA
Table 122: Possible system unit and CPU board combinations
5.2.2 Link modules
Information:
A corresponding Link module must be selected for each device used.
Model number
Description
Note
5DLDVI.1000-01
Automation Panel Link DVI receiver
Connections for DVI-D, RS232 and USB 2.0 (Type B); 24 VDC (order screw clamp 0TB103.9 or cage
clamp 0TB103.91 separately)
Table 123: Link modules
5.2.3 Cables
Select one Automation Panel 900 cable each from the 3 required types.
Model number
Description
Length
5CADVI.0018-00
DVI-D cable, 1.8 m
1.8 m ±50 mm
5CADVI.0050-00
DVI-D cable, 5 m
5 m ±80 mm
5CADVI.0100-00
DVI-D cable, 10 m
10 m ±100 mm
9A0014.02
RS232 extension cable for remote operation of a display unit with touch screen, 1.8 m
1.8 m ±50 mm
Table 124: Cables for DVI configurations