CLI Commands
Modem configuration – Console port
580 Avaya G450 CLI Reference
speed (PPP)
Use the
speed
command to set the PPP baud rate to be used by asynchronous PPP ports.
Note:
Note:
The peer baud rate must be set to the same value.
Syntax
speed
speed_rate
Parameters
User Level
read-write
Context
Interface: Console
Example
To set the PPP baud rate to 9600:
G450-001(if:CON)# speed 9600
Related Commands
,
timeout absolute
Use the
timeout absolute
command to set the number of minutes until the system
automatically disconnects an idle PPP incoming session.
Syntax
timeout absolute
time
Parameter
Description
Possible
Values
Default
Value
speed_rate
The PPP baud rate
9600
,
19200
,
38400
38400