background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

SNMP Agent / LoRaWAN Gateway

 

 

Document code: MN67F41_ENG     Revision 1.000   Page 1 of 33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

SNMP Agent / LoRaWAN Gateway - 
Converter 

 (Order Code:  HD67F41-B2-xxxMHz) 

 
 

For Website information:  

www.adfweb.com?Product=HD67F41-B2

  

 

For Price information: 

www.adfweb.com?Price=HD67F41-B2-xxxMHz

 

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Power Supply 12…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C  (-40°F/+185°F) 

 

For others LoRaWAN products, see also the following links: 

 

Converter LoRaWAN to  

www.adfweb.com?Product=HD67F01

        

(Modbus Master) 

www.adfweb.com?Product=HD67F02

        

(Modbus Slave) 

www.adfweb.com?Product=HD67F03

      

(Modbus TCP Master) 

www.adfweb.com?Product=HD67F04

 

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67F05

      

(Serial) 

www.adfweb.com?Product=HD67F15

      

(M-Bus) 

www.adfweb.com?Product=HD67F16

      

(BACnet Master) 

www.adfweb.com?Product=HD67F17

       

(BACnet Slave) 

www.adfweb.com?Product=HD67F18

       

(Ethernet) 

www.adfweb.com?Product=HD67F19

      

(CAN) 

www.adfweb.com?Product=HD67F20

      

(CANopen) 

www.adfweb.com?Product=HD67F21

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67F22

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67F23

      

(DMX) 

www.adfweb.com?Product=HD67F24

      

(EtherNet/IP Master) 

www.adfweb.com?Product=HD67F25

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67F26

      

(J1939) 

www.adfweb.com?Product=HD67F27

      

(KNX) 

www.adfweb.com?Product=HD67F28

      

(NMEA 0183) 

www.adfweb.com?Product=HD67F29

      

(NMEA 2000) 

www.adfweb.com?Product=HD67F30

      

(PROFIBUS Master) 

www.adfweb.com?Product=HD67F31

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67F32

      

(PROFINET Master) 

www.adfweb.com?Product=HD67F33

      

(PROFINET Slave) 

www.adfweb.com?Product=HD67F34

      

(IEC61850 Client) 

www.adfweb.com?Product=HD67F35

      

(IEC61850 Server) 

www.adfweb.com?Product=HD67F36

      

(MQTT) 

www.adfweb.com?Product=HD67F37

      

(OPC UA Client) 

www.adfweb.com?Product=HD67F38

      

(OPC UA Server) 

www.adfweb.com?Product=HD67F39

      

(S7comm) 

www.adfweb.com?Product=HD67F40

      

(SNMP Manager) 

 

User Manual   

 

Содержание HD67F18-B2 Series

Страница 1: ...BACnet Master www adfweb com Product HD67F17 BACnet Slave www adfweb com Product HD67F18 Ethernet www adfweb com Product HD67F19 CAN www adfweb com Product HD67F20 CANopen www adfweb com Product HD67...

Страница 2: ...ICAL SUPPORT 33 RETURN POLICY 33 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the prod...

Страница 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operati...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual SNMP Agent LoRaWAN Gateway Document code MN67F41_ENG Revision 1 000 Page 4 of 33 EXAMPLE OF CONNECTION...

Страница 5: ...ustrial Electronic Devices ADFweb com S r l User Manual SNMP Agent LoRaWAN Gateway Document code MN67F41_ENG Revision 1 000 Page 5 of 33 CONNECTION SCHEME Figure 1 Connection scheme for HD67F41 B2 xxx...

Страница 6: ...r Supply Mountable on 35mm Rail DIN Wide power supply input range 12 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67F41 software on your PC in or...

Страница 7: ...ENG Revision 1 000 Page 7 of 33 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24...

Страница 8: ...of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is use...

Страница 9: ...0 5Hz update in progress 2 LoRaWAN communication yellow Blinks when a LoRaWAN message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 SNMP communication yellow Bli...

Страница 10: ...ervices LoRaWAN network architecture is deployed in a star of stars topology in which gateways relay messages between end devices and a central network server The wireless communication takes advantag...

Страница 11: ...ing the device The Ethernet connection must be made using Connector3 of HD67F41 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to...

Страница 12: ...Converter use the available software that runs with Windows called SW67F41 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Win...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable SNMP Agent LoRaWAN Gateway Converter in order to configure another device in the same...

Страница 14: ...e the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible...

Страница 15: ...Agent LoRaWAN Gateway Document code MN67F41_ENG Revision 1 000 Page 15 of 33 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside...

Страница 16: ...0 Page 16 of 33 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67F41 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections...

Страница 17: ...NNECTION The means of the fields for Ethernet Connection are In the field Device Name Hostname the Hostname to assign to the converter is defined If the field Obtain an IP Address Automatically DHCP f...

Страница 18: ...bits order will be the same of the end devices definition inside the LoRaWAN Access section In the field RX2 Datarate the data rate on RX2 window is defined SNMP The means of the fields for SNMP Agent...

Страница 19: ...ser the user for the SNMP authentication is defined o In the field Security Level the type of security used is defined o In the field Authority the password for the SNMP authentication is defined o In...

Страница 20: ...enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field SSID the name of the Wi Fi network to create is defined In the field Secure Type the type of...

Страница 21: ...IP Address the IP address of the converter is defined In the field Subnet Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the net is defined This feature...

Страница 22: ...AN Gateway Set Access window LORAWAN ACCESS By Pressing the LoRaWAN Access button from the main window for SW67F41 Fig 2 the window LoRaWAN Gateway Set Access appears Fig 4 This section is used to def...

Страница 23: ...Key the Network session key for LoRaWAN connection is defined In the field Application Session Key the Application session key for LoRaWAN connection is defined In the field Application Key the Applic...

Страница 24: ...munication is defined In the field Start Test it is possible to define the starting byte to check offset inside the LoRaWAN message for recognizing specific LoRaWAN messages from end device optional I...

Страница 25: ...he LoRaWAN message to write from SNMP is defined In the field Number Bytes the number of consecutive bytes to write from starting byte is defined If the field On Change is checked the LoRaWAN message...

Страница 26: ...from LoRaWAN side change If the field On CMD is checked the OID is sent as Trap when the a LoRaWAN response is received If the field On Timer is checked the OID is sent as Trap cyclically In the fiel...

Страница 27: ...he OID is defined For Int type the dimension is in bit for String type the dimension is in bytes In the field Description the description name of the OID is defined In the field Conversion it is possi...

Страница 28: ...ernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1...

Страница 29: ...rogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 11 make sure that you have the administrator privileges In case you have to program...

Страница 30: ...Electronic Devices ADFweb com S r l User Manual SNMP Agent LoRaWAN Gateway Document code MN67F41_ENG Revision 1 000 Page 30 of 33 Figure 8 Mechanical dimensions scheme for HD67F41 B2 xxxMHz MECHANICAL...

Страница 31: ...cation 868 868 MHz 915 915 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting Device Family HD67F41 SNMP Agent LoRaWAN Gateway Converter Order Code HD67F41...

Страница 32: ...ction systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the re...

Страница 33: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product t...

Отзывы: