Industrial
Electronic Devices
ADFweb.com S.r.l.
User Manual
SNMP Agent / LoRaWAN Gateway
Document code: MN67F41_ENG Revision 1.000 Page 23 of 33
In the “
LoRaWAN Gateway Devices List
”, the list of LoraWAN end devices to connect is defined. The means of the fields for configuration
are:
If the field “
Enable
” is checked, the LoRaWAN end device is enabled;
In the field “
Device EUI
” the Device EUI for the LoRaWAN device is defined;
In the field “
Join EUI
” the Join EUI for the LoRaWAN device is defined;
In the field “
Device Name
” the name of the LoRaWAN device is defined;
In the field “
Activation Method
” the activation method for LoRaWAN device is defined;
In the field “
Network Session Key
” the Network session key for LoRaWAN connection is defined;
In the field “
Application Session Key
” the Application session key for LoRaWAN connection is defined;
In the field “
Application Key
” the Application key for LoRaWAN connection is defined;
In the field “
Device Address
” the address of the LoRaWAN device is defined;
In the field “
Class
” the Class of the LoRaWAN device is defined;
In the field “
Diag. TimeOut
” the timeout in ms for LoRaWAN communication is defined. If the LoRaWAN messages are received for
this timeout, the correspondent bit for the diagnostic of Modbus side is set to 1;
In the field “
RX2 Datarate
” the datarate used into the RX2 window is defined (optional).
In the field “
Mnemonic
” a description of the LoRaWAN device is defined.
Note:
It is recommended to set the “Diag. Timeout” with a higher time than the cyclic delay used by the LoRaWAN device to send data.