C.12 Option 17: Parallel BCD Output and Second RS-232 Port
143
Parallel Data Output Mode
Full operation in the parallel data output mode utilizes all 50 contacts of the output connector.
However, use of any combination of digital signal outputs or analog signal outputs, or RS-232C will
reduce the number of data bits available by up to four (data bits 19, 27, 44, and 45). For details,
refer to the sections pertaining to these individual functions.
The functions of the individual data bits are defined for specific customer applications, upon request.
To configure Option 17 for parallel data mode, observe the following steps:
a. Set jumper JMP1 to position ”B”. This jumper enables the parallel data output mode.
b. Set jumpers JMP2, JMP3, JMP4, JMP5, and JMP11 to position ”A” (these settings will vary
if the analog and/or digital signal outputs or RS-232C port are used; refer to the applicable
sections for more information on these functions).
c. If it is desired that the parallel output data be synchronous to the 1 PPS output, set jumper
JMP6 to position ”A”; for non-synchronous operation, set this jumper to position ”B”.
Digital Signal Outputs
The four digital signal outputs can be individually enabled and configured, using the following
steps:
a. Set jumper JMP11 to position ”A”. This enables the digital signal output mode. At the
same time, making this jumper selection eliminates parallel data bits 19, 27, 44, and 45.
b. To enable digital signal output number 1, set jumper JMP2 to position ”A”.
This also
eliminates the TXD RS-232C line.
c. To set the type of output signal for digital signal output number 1, make the appropriate
selection on jumper JMP8 (refer to Figure 2). Note that positions 1 and 2 correspond to
analog signal outputs, and will be occupied by a jumper only if analog signal output number
1 is enabled.
d. To enable digital signal output number 2, set jumper JMP3 to position ”A”.
e. To set the type of output signal for digital signal output number 2, make the appropriate
selection on jumper JMP7 (refer to Figure 2). Note that positions 1 and 2 correspond to
analog signal outputs, and will be occupied by a jumper only if analog signal output number
2 is enabled.
f. To enable digital signal output number 3, set jumper JMP4 to position ”A”.
This also
eliminates the possibility of using analog signal output number 1.
g. To set the type of output signal for digital signal output number 3, make the appropriate
selection on jumper JMP9 (refer to Figure 2).
h. To enable digital signal output number 4, set jumper JMP5 to position ”A”.
This also
eliminates the possibility of using analog signal output number 2.
i. To set the type of output signal for digital signal output number 4, make the appropriate
selection on jumper JMP10 (refer to Figure 2).
Содержание 1088A
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 18: ...xviii LIST OF FIGURES ...
Страница 23: ...1 4 Attaching Rack Mount Ears to 1088A B Series Clocks 3 Figure 1 2 Attaching Rack Mount Ears ...
Страница 24: ...4 Unpacking the Clock ...
Страница 32: ...12 Front and Rear Panels ...
Страница 38: ...18 Connecting Inlet Power Input and Output Signals ...
Страница 41: ...4 1 GPS Antenna Installation 21 Figure 4 2 Antenna Mounting Bracket Figure 4 3 Antenna Mounting with AS0044600 ...
Страница 46: ...26 GPS Antenna and Cable Information ...
Страница 48: ...28 Setting Internal Jumpers Figure 5 1 Model 1088B Main Board ...
Страница 76: ...56 The Setup Menus ...
Страница 112: ...92 Serial Communication and Command Set ...
Страница 127: ...B 4 Physical Dimensions 107 Figure B 1 Suggested Mounting of the AS0094500 Surge Arrester ...
Страница 128: ...108 Using Surge Arresters ...
Страница 137: ...C 5 Option 04 Parallel BCD Output 117 C 5 2 Option 04 Firmware Setup Figure C 2 Option 04 Firmware Setup ...
Страница 145: ...C 5 Option 04 Parallel BCD Output 125 Figure C 4 Option 04 Output Jumper Settings ...
Страница 146: ...126 Options List Figure C 5 Option 04 Board Layout and Jumper Locations ...
Страница 165: ...C 12 Option 17 Parallel BCD Output and Second RS 232 Port 145 Figure C 11 Option 17 Output Jumper Settings ...
Страница 166: ...146 Options List Figure C 12 Option 17 Board Layout and Jumper Locations ...
Страница 176: ...156 Options List C 14 5 Typical Network Configuration Figure C 15 Option 18 Network Configuration ...
Страница 187: ...C 16 Option 20A Four Fiber Optic Outputs 167 Figure C 22 Option 20A Jumper Locations ...
Страница 194: ...174 Options List Figure C 24 Option 23 Internal Jumper Setup ...
Страница 196: ...176 Options List Figure C 25 Option 27 Jumper Locations ...
Страница 214: ...194 Options List Figure C 28 Option 29 Connector Signal Locations ...
Страница 270: ...250 Options List ...