Page 58 of 130
Primarily used where the Star Configuration Point is in the NIB.
It is also used in trailer park installations where the NIB is placed on a 4 x 4 post, and the Star Configuration
point is at the post.
Figure 63: Tii 80-410V-11
1. Used inside the home
2. Can also be used in small MDUs
Both are VDSL2 compliant and use insulation displacement connection technology.
1.9 Alarm Jacks
Residential alarms also need to be taken into account for single-dwelling installations.
8 pin shorting jacks in an RJ45 configuration are usually installed by the alarm company. Sometime they will
be installed, but not wired. The alarm company may leave a note asking us to wire this for them. They go
between the telephone service and the residential alarm equipment.
Figure 64: RJ 45 Style alarm Jack
Basic alarm jack wiring
This diagram shows basic alarm jack wiring:
1. Dial tone is on the pair from the protector.