Parameters 311
0.0…35880.0 rpm
Speed
SLSx.44 SLS4 output
Sets the digital output that is connected to
the output of the SLS4 function. Active when
SLS4 function is active and the motor speed
is below the SLS4 limit (that is, when the
SLS4 monitoring is on).
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
SLSx.51 Variable SLS output Sets the digital output that is connected to
the output of the Variable SLS function.
Active when Variable SLS function is active
and the motor speed is below the Variable
SLS limit (that is, when the Variable SLS
monitoring is on).
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
41
SMS
Parameters for the SMS function
SMS.13 SMS trip limit
negative
Sets the negative speed limit that trips the
drive for the SMS function.
0.0 rpm
-35880.0 …0.0 rpm Speed
SMS.14 SMS trip
limit
positive
Sets the positive speed limit that trips the
drive for the SMS function.
0.0 rpm
0.0 …35880.0 rpm Speed
Index
Name/Value
Description
Factory
default
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...