![ABB FSO-12 Скачать руководство пользователя страница 156](http://html.mh-extra.com/html/abb/fso-12/fso-12_user-manual_2726156.webp)
156 PROFIsafe
Fail-safe
The FSO application keeps the system in the Fail-safe mode. PROFIsafe
communication is up and running.
This state is reached if a fatal error (for example, CPU test, RAM test, I/O
channel test etc. failed) takes place.
The drive is stopped using the configured method. In the end, the drive
STO is activated. The fail-safe value “0” is set to all I/O channels. The fail-
safe value “0” is transferred to the safety PLC for all I/O channels.
This state can be left only to the Start-up mode by cycling power of the
FSO module or by giving the reset command via the drive (parameter
96.09 FSO reboot
, see the drive firmware manual).
PROFIsafe Status Byte bits in the F-Host for the FSO module:
• OA_Req_S = 0
• FV_activated_S = 1
• Device_Fault = 1
ABB_PS1 profile bits in the F-Host for the FSO module:
• FSO_mode.1 = 1
• FSO_mode.0 = 0
• SF_end_ack_req_local = 0
• SF_end_ack_req = 0
• FSO_state =1
See also the Note on page
.
Configuration
The FSO module is in the Safe state. Upon transferring to the
Configuration mode, the FSO answers to one PROFIsafe frame. The fail-
safe value “0” is transferred to the safety PLC for all I/O channels. After
that PROFIsafe communication is not possible. The fail-safe value “0” is
set to all I/O channels.
This state can only be entered from the Fail-safe mode or from any other
state when the drive is not modulating.
This state can be left only to the Start-up mode by cycling power of the
FSO module or by giving the reset command via the drive (parameter
96.09 FSO reboot
, see the drive firmware manual).
PROFIsafe Status Byte bits in the F-Host for the FSO module:
• OA_Req_S = 0
• FV_activated_S = 1
• Device_Fault = 0
ABB_PS1 profile bits in the F-Host for the FSO module:
• FSO_mode.1 = 1
• FSO_mode.0 = 1
• SF_end_ack_req_local = 0
• SF_end_ack_req = 0
• FSO_state = 1
See also the Note on page
.
State
Description
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...