146 PROFIsafe
2
0
Reserved
*)
Note:
This value should only be used for octet 5 bit 3
Speed_Pos_value_valid interpretation, that is, to
determine if the position value is valid or not (octet 8 and
9). The value is 0. Must be ignored by the F-Host.
1
SMS_active
SMS (Safe maximum speed) function is active.
2
Reserved
*)
The value is 0. Must be ignored by the F-Host.
3
Reserved
*)
The value is 0. Must be ignored by the F-Host.
4
Reserved
*)
The value is 0. Must be ignored by the F-Host.
5
Reserved
*)
The value is 0. Must be ignored by the F-Host.
6
Reserved
*)
The value is 0. Must be ignored by the F-Host.
7
Reserved
*)
The value is 0. Must be ignored by the F-Host.
3
0
Safe_input_X114_4
State of the safe input X114:4.
1
Safe_input_X114_3
State of the safe input X114:3.
2
Safe_input_X114_2
State of the safe input X114:2.
3
Safe_input_X114_1
State of the safe input X114:1.
4
Safe_input_X113_4
State of the safe input X113:4.
5
Safe_input_X113_3
State of the safe input X113:3.
6
Safe_input_X113_2
State of the safe input X113:2.
7
Safe_input_X113_1
State of the safe input X113:1.
4
0
Variable_SLS_active Variable SLS (Safely-limited speed) is active. Active when
the Variable SLS function is active and the motor speed is
below the Variable SLS limit (that is, when the Variable
SLS monitoring is on).
1
POUS_active
POUS (Prevention of unexpected start-up) function is
active.
2
Safe_output_X114_9 State of the safe output X114:9.
3
Safe_output_X114_8 State of the safe output X114:8.
4
Safe_output_X114_7 State of the safe output X114:7.
5
Safe_output_X113_9 State of the safe output X113:9.
6
Safe_output_X113_8 State of the safe output X113:8.
7
Safe_output_X113_7 State of the safe output X113:7.
Octet Bit Name
Description
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...