Technical data 371
16
Technical data
Contents of this chapter
This chapter contains the technical specifications of the FSO-12 module.
Electrical data
PROFIsafe and related network devices
All network devices used in conjunction with this device shall meet the requirements
of IEC 61010-1 or IEC 61131-2.
Supply voltage
+24 ± 3 V DC (SELV/PELV)
Current consumption
Maximum 1000 mA (external power supply)
Inputs
4 redundant or 8 single, or combinations of redundant and
single, 24 V DC NPN
Maximum time delay between redundant input channels: 300 ms
Outputs
3 redundant or 6 single, or combinations of redundant and
single, 24 V DC PNP
EMC
Complies with EMC standards EN 61800-3:2004 and
IEC 61000-6-7:2014. Max. STO cable length: see
and data cable between FSO module and drive
on page