Variable SLS with time monitoring
In Variable SLS with time monitoring, the ramp according to which the drive
decelerates the motor to different speeds is monitored using the time monitoring
method.
Drive parameters define the deceleration ramp. If the motor speed is
accelerated, drive parameters define the acceleration ramp and it is not monitored.
For configuration, see section
How to configure Variable SLS with time monitoring
page
A
Variable SLS trip limits (parameter
and the scaling values set in the safety PLC)
B
SLS time delay (parameter
): Delay for forcing to start SLS monitoring.
C
Response time (depends on system configuration, see page
Variable SLS trip limit (A)
Step
Description
1
The Variable SLS request is received from the safety PLC (for example, 70%). The
FSO sends a request to the drive to ramp down the motor speed to the new SLS speed
limit. The FSO start a counter for the SLS time delay (B).
2
After time C has elapsed, the drive starts to ramp down the motor speed.
The drive
(parameter
23.13
or
23.15
) defines the deceleration ramp.
The FSO starts the SLS monitoring when the motor speed is in the middle of the new
SLS limit and the SLS trip limit (see also section
How to fine-tune when monitoring is
on page
3
The new motor speed has been reached. The Variable SLS indication (parameter
) goes on.
4
The FSO starts the SLS monitoring at the latest here, that is, after the SLS time delay
(B) has elapsed.
Note
: If the motor speed is above the SLS trip limit after the SLS time delay (B) has
elapsed, the FSO module activates the SSE function. For more information, see
section
SLS with time monitoring and speed above monitored speed
on page
.
varSLS status
& indication
C
2
5
varSLS request
4
B
Motor speed
Time
6
7
8 9 10
11 12
B
A
C
C
A
A
3
1
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...