Configuration 221
No. Phase
1.
&
2.
Risk assessment & Safety requirements
• analysis and evaluating of the risks
• need for risk reduction
• required PL or SIL level
• speed limits and distances for safety functions.
3.
Planning of the configuration of the FSO
How to do the safety configuration in a safe way, including configuration,
commissioning, validation and verification.
4.
Design of the safety functions
Selected safety functions and related parameter settings must be based on
the risk assessment and the safety requirements of the application. For
example:
• safely limited speed (SLS) trip limits
• settings of I/O’s
• selection of the stopping function
• diagnostics and fault reaction, etc.
5.
Commissioning of the FSO
• configuring and fine tuning of the safety parameters of the FSO module
• commissioning of the PROFIsafe connection to the safety PLC
• electrical installation, etc.
6.
Validation of the functional safety system
Validation of the safety functions which are used in the safety system: They
operate as required in the application, and the safety requirements (SRS)
arising from the risk assessment are fulfilled.
If any of the safety functions does not pass the validation tests, it is
necessary to return to the design phase, and modify the safety function so
that it fulfills the safety requirements from the risk assessment. After the
modification, the validation test(s) must be repeated and passed.
See chapter
7.
Validation test report
Validation must be properly documented and stored.
See section
on page
8.
Modification
After the modifications, the validation tests must be repeated and passed.
9.
Decommissioning
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...