Overview 39
from an FSO internal fault. Some safety functions can be permanently active. If the
drive does not fulfill the commands of the FSO, the FSO stops the drive modulation
using the Safe torque off (STO) function.
If the drive is connected to a safety PLC, the safety of the fieldbus communication
can be secured with the PROFIsafe over PROFINET technology. The safety PLC is
connected to the FENA-21 fieldbus adapter module, which communicates with the
FSO module. For more information, see chapter
.
Safety functions supported by the FSO module are presented in chapter
.
FSO module version handling
To ensure backward and forward compatibility with the ACS880 drives, the FSO-12
module has a version handling system. Both the FSO module and the ACS880 drive
firmware must support the used safety functions.
You can always replace the FSO-12 module with a newer revision and use the same
configuration file with the new revision. Each time you make any changes in the
safety system, you must do the acceptance test to each safety function using the
checklists described in chapter
Note:
Due to an update in functionality related to a situation where drive modulation
is lost when SLS function is active, it is recommended to update all FSO modules to
revision H (or later).
Each new revision of the FSO-12 module supports all or most functions of previous
FSO-12 module revisions and it can be used together with previous ACS880 drive
firmware versions. In addition, previous FSO-12 module revisions can be used
together with new ACS880 drive firmware versions. In this case, the drive supports
only the functions of the previous FSO-12 module revision. For more information on
product compatibility, see section
on page
Each safety function and parameter group has a separate version parameter. With
these parameters, the user selects the desired versions according to the drive
firmware and FSO-12 module combination at the start-up. Only the versions that both
the used ACS880 drive firmware and the FSO-12 module support are shown in the
Drive composer pro PC tool.
Example
: Revision A of the FSO-12 module has one version of the SMS function
(Version 1). Revision C has two versions the SMS function (Version 1 and Version 2).
If the used ASC880 drive firmware supports both versions, the user can find them in
the parameter list and select the desired version. If the used ACS880 drive firmware
supports only Version 1 of the SMS function, only Version 1 is shown in the parameter
list.
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...