254 Configuration
Example 2:
The figure below shows an example of the SSE with emergency ramp
function with speed limit activated SBC set-up with ramp monitoring:
• SSE with emergency ramp (
=
Emergency ramp
)
• SAR0 emergency ramp (always with the SSE function)
• SAR0 monitored ramp (
=
Ramp
, see also
section
)
• redundant emergency stop button connected to input
=
DI X113:1 & X114:1
)
• single output connected (
= DO X113:9
)
• brake connected to redundant output, diagnostic pulses activated
=
DO X113:7 & X114:7
and
=
On
)
• speed limit activated brake in use, speed below which the brake and STO are
activated 240.0 rpm (
240 rpm
)
• delay for activating STO after brake is zero (STO and SBC are activated at the
same time) (
=
0 ms
)
• delay for activating the brake and drive STO after the speed limit has been
reached 0 ms (
SSE ramp zero speed delay for STO
0 ms
)
• STO is activated if brake feedback fails (
=
STO
)
• brake feedback input connected to input
=
DI X113:2
)
• feedback input type NC (inverted state compared with the brake relay)
Mechanically linked NC contacts
).
• See also section
.
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...