Configuration 223
Note:
Make sure that the diagnostic pulsing settings are compatible with
all devices in the system (for example, switches, light curtains and PLCs).
•
Safety functions: You must at least check and set the parameters related
to the STO and SSE functions, regardless of what you use the FSO for or
which safety functions you use. The FSO can activate the STO and SSE
functions in internal fault situations. The STO and SSE functions are
essential for the FSO to be able to make the system safe.
e. After configuring all necessary functions, do these two steps:
•
Save the configuration to your PC (button
Save to file
).
•
Download the configuration to the FSO (button
Apply setting to drive
). A
password is required.
f. After downloading, the FSO and the tool validate the configuration, and the
tool asks you to confirm the validation.
g. Change the password to protect the settings (button
Change password
). A
password is required.
Note:
The motor must be stopped when you change the password.
3. Validate safety functions, print the report from the configuration, including all the
values of the parameters and CRC. Sign and store the report according to your
safety management plan.
Note
: You can use the safety report in the Drive
composer pro PC tool for this purpose.
Note:
Make sure you saved the safety file after validation for later use. The safety file
is not included in the drive backup process.
Note:
If you want to clear the configuration and start again from the factory setup, do
a factory reset. See section
Factory reset
on page
242
.
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...