20 Introduction to the manual
Common cause
failure (CCF)
Failure, which is the result of one or more events, causing coincident
failures of two or more separate channels in a multiple channel
(redundant architecture) subsystem, leading to failure of a Safety
related electronic control function (SRCF).
Communication
module
Communication module is a name for a device (eg, a fieldbus adapter)
through which the drive is connected to an external communication
network (eg, a fieldbus). The communication with the module is
activated with a drive parameter.
Controller
Control system with bus initiative (master). In PROFINET IO
terminology, controller stations are also called active stations.
Control word
16-bit word from controller to device with bit-coded control signals
(sometimes called the Command word).
CRC
Cyclic redundancy check
Cyclic
communication
Communication in which parameter/process data objects are sent
cyclically at pre-defined intervals
DAT
Device acknowledgement time
DC
Diagnostic coverage (%) (EN ISO 13849-1), Direct current
Device
Passive bus participant. In PROFINET IO terminology, device stations
(or slaves) are also called passive stations. Also referred to as nodes.
DI
Digital input
DO
Digital output
E-stop
Emergency stop
ELV
Extra-low voltage
EMC
Electromagnetic compatibility
External active load
Load in systems where the motor speed does not decrease when the
motor control is stopped.
Fail-safe mode
The FSO module has activated the drive STO function as a result of an
error (in some cases, after a delay). To exit this mode and continue
normal operation, reboot the FSO module.
FbEq16
16-bit fieldbus equivalent: The scaling between the value shown on the
panel and the integer used in communication when a 16-bit value is
selected for transmission to an external system.
FbEq32
32-bit fieldbus equivalent: The scaling between the value shown on the
panel and the integer used in communication when a 32-bit value is
selected for transmission to an external system.
F-Device
Device that is able to communicate using PROFIsafe, eg, the FSO
module.
F-Host
Programmable logic controller (PLC) that is able to communicate using
PROFIsafe.
F-Input
PROFIsafe frame user data from that is sent from the F-Device (FSO) to
the F-Host (PLC).
Term /
Abbreviation
Description
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...