50 Safety functions
Limit hit
: If the motor speed hits a ramp monitoring limit, the FSO module activates
the STO function and generates an event. The user can select the event type
(warning, fault or event) with parameter
.
Function indications
The logic state of output indication signals can be configured to be active low or
active high.
STO, SS1, SSE, POUS
States of the configured and connected functions are indicated with FSO digital
outputs and fieldbus status signals when the function is started:
• Stopping functions (SSE and SS1) are always started and indicated immediately
(the monitoring method depends on the configuration)
(parameters
and
• The drive STO state is indicated when the drive STO circuit is open
(parameter
).
Note
: When the SBC is activated before the drive STO, the drive STO is indicated
after a delay (parameter
• POUS function is indicated immediately when requested from an input
• Ramp monitoring (SAR0 and SAR1, see section
on page
) is
not indicated.
The FSO module switches off the digital output indications (SSE, SS1 and POUS
functions) when the function is acknowledged.
Stop completed indications
are activated when the stopping function has completed,
but is not yet acknowledged. There are separate indications for each stopping
function STO, SSE and SS1 (parameters
) and one common for all of
them (parameter
). The FSO module switches off
the indications when the function is acknowledged.
The completed indication of the POUS function (parameter
) is activated after the time defined by parameter
has passed. The FSO module switches off the completed
indication when the POUS request is removed.
SLS, Variable SLS
• SLS indication starts when the motor speed is in the monitored range. The FSO
module switches off the indication when the function is acknowledged or the
monitored speed exceeds the user-defined limit (this also causes the SLS to trip,
that is, the FSO module activates the SSE function).
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...