300 Parameters
SSE.13 SSE function
Sets the type of the SSE function.
Immediate STO
The FSO module activates the drive STO
immediately after the SSE request.
Emergency ramp
The FSO module activates the drive STO
after an emergency ramp.
SSE.14 SSE monitoring
method
Sets the method used for the SSE
emergency ramp monitoring. This parameter
is relevant only if parameter
is set to
Ramp
Ramp monitoring. SAR0 parameters define
the emergency ramp and monitoring limits.
See parameters
and
.
Time
defines the emergency
ramp and it is monitored with parameter
SSE.15 SSE delay for STO
Sets the security delay after which the FSO
module actives the STO after the SSE
request.
This parameter is relevant only if parameter
, time monitoring is used (
) and the motor
speed does not follow the ramp.
3,600,000
ms
0…3,600,000 ms
Time
Index
Name/Value
Description
Factory
default
Содержание FSO-12