262 Configuration
Configuring Variable SLS
This safety function requires that a safety PLC is connected to the FSO module via
the PROFIsafe communication bus. For more information, see chapter
and section
Configuring the safety fieldbus communication
on page
To configure the Variable SLS function, set the FSO parameters listed below to
appropriate values using the Drive composer pro PC tool. See parameter groups
on page
The Variable SLS function uses the SLS4 limits of the FSO module. Depending on
the application, set the negative and positive SLS and trip limits separately.
The FSO module scales the SLS4 trip limit so that the difference between the new
limits does not become too small. For more information, see section
scaled SLS4 limit and SLS4 trip limits
For more information on the Variable SLS function, see page
How to configure Variable SLS with time monitoring
Example:
The figure below shows an example of the Variable SLS function with time
monitoring set-up:
• Variable SLS function activated
SLS variable activity and version
=
Version 1
)
• automatic acknowledgement (
=
Automatic
)
• time monitored deceleration ramp
SLS activation monitoring method
Time
)
• deceleration and acceleration ramps according to drive parameters
• SLS activation delay: 2000 ms (
2000 ms
)
• single output connected (
DO X114:7
)
• positive limits: SLS 1200.0 rpm, trip limit 1320.0 rpm
=
1200 rpm,
=
1320 rpm
).
• negative limits: SLS -100 rpm, trip limit: -150 rpm
, not shown in the figure)
=
-100 rpm,
-150 rpm
).
• See also section
.
Note
: The difference between the SLS limit and the corresponding SLS trip limit must
be at least 0.1 rpm.
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...