Program features 85
internal resistance of the digital input from the analog input and calculates the PTC
resistance.
Note:
RIIO-01 or BIO-01 is required for the analog input. By default, RIIO-01 is
provided with the ACS560 drives.
Example settings
The parameters are set as follows for monitoring the temperature with PTC sensors:
WARNING!
IEC 60664 requires double or reinforced insulation between live
parts and the surface of accessible parts of electrical equipment which are
either non-conductive or conductive but not connected to the protective. Obey
the electrical planning guidelines for implementing the motor temperature sensor
connection. If you ignore them, injury or death, or damage to the equipment can
occur
For wiring of the sensor, refer to the drive hardware manual.
Make sure that the DI used is not configured to any other use in the drive control
program.
Temperature monitoring using Pt100 sensors
1…3 Pt100 sensors can be connected in series to an analog input and an analog
output.
The analog output feeds a constant excitation current of 9.1 mA through the sensor.
The sensor resistance increases as the motor temperature rises, as does the voltage
Parameter
Value
PTC analog I/O (20). For R0...R2 frames, it can
be PTC AI/DI Voltage Divider tree (23) also.
AI1
V
Temp sensor 1 excitation (20).
Note:
This is not applicable for R0...R2, if PTC
AI/DI Voltage Divider tree is used.
Desired value
T
T
T
1...3 x PTC
DIn
AIn
+10 V
Содержание ACS560
Страница 1: ...ABB GENERAL PURPOSE DRIVES ACS560 standard control program Firmware manual...
Страница 4: ...4...
Страница 30: ...30 Start up control with I O and ID run...
Страница 32: ...32 Using the control panel...
Страница 100: ...100 Program features...
Страница 153: ...Control macros 153...
Страница 160: ...160...
Страница 374: ...374 Parameters...
Страница 408: ...408 Additional parameter data...
Страница 466: ...466 Fieldbus control through the embedded fieldbus interface EFB...
Страница 504: ...504 Control chain diagrams...
Страница 508: ...508 Parameterization with drive composer...
Страница 512: ...512 Parameterization with automation builder drive manager...