Program features 65
Motor control
Motor types
The drive supports asynchronous AC induction.
Motor identification
The performance of vector control is based on an accurate motor model determined
during the motor start-up.
A motor Identification magnetization is automatically performed the first time the start
command is given. During this first start-up, the motor is magnetized at zero speed
for several seconds and the motor and motor cable resistance are measured to allow
the motor model to be created. This identification method is suitable for most
applications.
In demanding applications a separate Identification run (ID run) can be performed.
Settings
(page
Scalar motor control
Scalar motor control is the default motor control method. In scalar control mode, the
drive is controlled with a frequency reference.
ABB recommends to activate the scalar motor control mode in the following
situations:
• If the exact nominal motor values are not available or the drive needs to run
different motors after commissioning.
• If a short commissioning time is needed.
• If ID run is not required.
• In multimotor systems:
•
if the load is not equally shared between the motors
•
if the motors are of different sizes
•
if the motors are going to be changed after motor identification (ID run)
• If the nominal current of the motor is less than 1/6
th
of the nominal output current
of the drive
Note:
During this time, do not activate the motor phase loss fault (
) as the drive cannot measure the motor current accurately.
• If the drive is used without a motor connected (for example, for test purposes)
• If the drive runs a medium-voltage motor through a step-up transformer.
• If the drive is equipped with a sine filter.
Note:
Performance of the vector control is not achieved in scalar control.
Содержание ACS560
Страница 1: ...ABB GENERAL PURPOSE DRIVES ACS560 standard control program Firmware manual...
Страница 4: ...4...
Страница 30: ...30 Start up control with I O and ID run...
Страница 32: ...32 Using the control panel...
Страница 100: ...100 Program features...
Страница 153: ...Control macros 153...
Страница 160: ...160...
Страница 374: ...374 Parameters...
Страница 408: ...408 Additional parameter data...
Страница 466: ...466 Fieldbus control through the embedded fieldbus interface EFB...
Страница 504: ...504 Control chain diagrams...
Страница 508: ...508 Parameterization with drive composer...
Страница 512: ...512 Parameterization with automation builder drive manager...