Interfaces (IEEE option L45-O1) LMG450
216
Reads and sets the system time. Format is TIME hh,mm,ss. Example: TIME 10,26,46 sets the
time to 10:26:46.
10.2.13.10 :VERSion?
VER?
SCPI:
:SYSTem:VERSion? /qonly/
SHORT: VER? /qonly/
ID:
n/a
Mode:
All
Type:
n/a
Suffix:
n/a
Value:
1999.0
List:
n/a
Unit:
n/a
Group:
n/a
Returns the version of the SCPI implementation. Returns always ‘1999.0’.
10.2.14 :TRIGger commands
:CALCulate
:DISPlay
:FETCh
:FORMat
:INITiate
:INPut
:INSTrument
:MEMory
:READ
:SENSe
:SOURce
:STATus
:SYSTem
:TRIGger
→
:ACTion
:ICURrent
:INTerval
[:SEQuence]
10.2.14.1 :ACTion
ACTN
SCPI:
:TRIGger:ACTion/nquery/
SHORT: ACTN/nquery/
ID:
n/a
Mode:
All
Type:
n/a
Suffix:
n/a
Value:
n/a
List:
n/a
Unit:
n/a
Group:
n/a
Defines an action which has to be performed, when :INIT:CONT is set to ON and a trigger
event occurs. All program headers which follow behind the ‘;’ after TRIG:ACT will be used,
until the end of the program message.
Example: ACTN;UTRMS?;ITRMS?
This defines that each time a trigger event occurs in the INIT:CONT ON state, the TRMS
values of voltage and current are returned. See also 10.2.6.1, ‘:CONTinuous
CONT’. The
Summary of Contents for LMG450
Page 1: ...4 Channel LMG450 Power Meter User manual Status 2009 02 17...
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 22: ......
Page 36: ......
Page 76: ......
Page 102: ......
Page 112: ......
Page 118: ......
Page 124: ......
Page 230: ......
Page 240: ......
Page 292: ......