Interfaces (IEEE option L45-O1) LMG450
166
Bit 1: Set if any of the harmonics was > 100% of the allowed limit, cleared otherwise.
Bit 2: Set if the voltage amplitude was not within the limit, cleared otherwise.
Bit 3: Set if the frequency was not within the limit, cleared otherwise.
Bit 4: Set if the crest factor was not within the limit, cleared otherwise.
Bit 5: Set, if the peak value is not within 90°
±
3°
10.2.4.1.7.9.3 :HWCFactor?
FLCF?
SCPI:
:FETCh[:SCALar]:HARMonics[:VOLTage]: HWCFactor? /qonly/ <list>|
:READ[:SCALar]:HARMonics[:VOLTage]: HWCFactor? /qonly/ <list>
SHORT: FLCF? /qonly/ <list>
ID:
n/a
Mode:
prCE
Type:
float
Suffix:
1...4
Value:
n/a
List:
0...31 for half wave number
Unit:
n/a
Group:
n/a
Reads the voltage crest factor of the half waves. After each measuring cycle over 16 periods
you can get 32 values.
10.2.4.1.7.9.4 :IAMPlitude?
HUZA?
SCPI:
:FETCh[:SCALar]:HARMonics:VOLTage:IAMPlitude? /qonly/ |
:READ[:SCALar]:HARMonics:VOLTage:IAMPlitude? /qonly/
SHORT: HUZA? /qonly/
ID:
n/a
Mode:
prCE
Type:
float
Suffix:
0...4
Value:
n/a
List:
0...5 for interharmonics number relative
to start position
Unit:
V
Group:
n/a
Reads the interharmonics of the voltage. To define the analysis area see command 10.2.10.8.2,
‘:ISTart
HNRZ’
10.2.4.1.7.9.5 :LIMit?
HULM?
UL
SCPI:
:FETCh[:SCALar]:HARMonics[:VOLTage]:LIMit? /qonly/ <list> |
:READ[:SCALar]:HARMonics[:VOLTage]:LIMit? /qonly/ <list>
SHORT: HULM? /qonly/ <list>
ID:
UL
Mode:
prCE
Type:
float
Suffix:
1...4
Value:
n/a
List:
0...40 for order
Unit:
V
Group:
n/a
Reads the limits of the harmonics of the voltage.
Summary of Contents for LMG450
Page 1: ...4 Channel LMG450 Power Meter User manual Status 2009 02 17...
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 22: ......
Page 36: ......
Page 76: ......
Page 102: ......
Page 112: ......
Page 118: ......
Page 124: ......
Page 230: ......
Page 240: ......
Page 292: ......