List of Commands
A list of commands that can be used on the PC link module is given below. For details,
refer to “Personal Computer Link Command” Manual (IM34M6P41-01E).
Table A2.1 Device Bit Access Commands
Command
ASCII
Function
Number of Points Handled per
Communication
"BRD"
Reads bits.
1-256 bits
"BWR"
Writes bits.
1-256 bits
"BFL"
Writes bits of the same data
1-256 bits
"BRR"
Reads bits randomly.
1-32 bits
"BRW"
Writes bits randomly.
1-32 bits
"BRS"
Specifies the devices to be monitored in bit unit.
1-32 bits
"BRM"
Monitors bits.
1-32 bits
Table A2.2 Device Word Access Commands
Command
ASCII
Function
Number of Points Handled per
Communication
"WRD"
Reads words.
1-64 words
"WWR"
Writes words.
1-64 words
"WFL"
Writes words of the same data
1-256 words
"WRR"
Reads words randomly.
1-32 words
"WRW"
Writes words randomly.
1-32 words
"WRS"
Specifies the devices to be monitored in word unit.
1-32 words
"WRM"
Monitors words.
1-32 words
Table A2.3 Special Module Access Commands
Command
ASCII
Function
Number of Points Handled per
Communication
"SWR"
Reads words.
1-64 channels (words)
"SWW"
Writes words.
1-64 channels (words)
"SLR"
Reads long words.
1-32 channels (words)
"SLW"
Writes long words.
1-32 channels (words)
Special modules refer to analog input/output modules, advanced positioning modules, GP-IB communications modules, etc.
Table A2.4 Sequence Program Access Commands
Command
ASCII
Function
"PRI"
Reads program information.
"PLC" Cancels
program loading or saving.
"PLD"
Loads a program.
"PSV"
Saves a program.
"STA"
Starts a program.
"STP"
Stops a program.
"PLX"
Loads a program (for 1024 blocks)
*1
"PSX"
Saves a program (for 1024 blocks)
*1
These commands are used for sequence CPUs. It is not supported for BASIC CPUs.
*1:
Load/Save commands for 1024 blocks are only supported by this module.
Programming ports of F3LC11- N, F3LE01-5T, CPU modules are not supported (as of 31
st
January 2001).
Table A2.5 Test Commands
Command
ASCII
Function
"TST"
Performs a (loopback) test.
Table A2.6 Miscellaneous Commands
Command
ASCII
Function
"MDR"
Resets the module.
"INF"
Reads information (CPU operating status, I/O configuration,
ERR/ALM factor, etc.).
"DTR"
Reads date and time.
"DTW"
Writes date and time.
"ERH"
Reads error log.
"ULR"
Reads user log
*1
*1:
Do not use this command on a BASIC CPU because the user log function is not available.
Summary of Contents for F3LC11-1F
Page 2: ......
Page 12: ...Blank Page...
Page 48: ...Blank Page...
Page 65: ...A3 7 IM 34M6H41 02E 2nd Edition Aug 1 2005 00 430 PR CLOSE 440 450 FIN 460 470 END...
Page 74: ...Blank Page...
Page 82: ...Blank Page...
Page 92: ...Blank Page...
Page 94: ...Blank Page...
Page 120: ...Blank Page...
Page 136: ...B3 6 IM 34M6H41 02E 2nd Edition Aug 1 2005 00 450 460 END...
Page 140: ...Blank Page...
Page 142: ...Blank Page...
Page 146: ...Blank Page...
Page 148: ...Blank Page...
Page 168: ...Blank Page...
Page 176: ...Blank Page...
Page 200: ...Blank Page...
Page 202: ...Blank Page...