C4-10
IM 34M6H41-01E
3rd Edition : Aug. 1, 2005-00
[4]
Devices that can be Specified
The device names that can be specified in each type of command are shown in Table 4.3.
Use a comma (,) or a space ( ) to delimit parameters.
The device names are represented using six characters (number of bytes). Abbreviations
may be used.
(X00201 and V00002 can be abbreviated as X201 and V02 or V2, respectively.)
(Example) To read 5 points of data from input relay X00201 of CPU number 1 in station
number 2 with a response wait time of 100 ms.
STX 0
2
0
1
A
B
R
D
X
0
0
2
0
1
,
0
0
5
Parameter
Command
Response wait time code
CPU number
Station number
FC040101_5.EPS