3-4
IM AQ6370C-17EN
Configuring the Remote Monitor Settings (On the AQ6370C/AQ6370D/
AQ6373B/AQ6375B)
21.
Press the
REMOTE MONITOR
soft key. The remote monitor setup menu appears.
22.
Press the
MONITOR PORT
soft key. Each time you press the soft key, the setting
toggles between ON and OFF. Remote monitoring is possible when the setting is
ON.
Turns the monitor port on and off.
Set the port number (fixed).
Disconnects the monitor connection
• Disconnecting the Monitor Connection
23.
Press the
DISCONNECT
soft key. The monitor connection from the PC is
disconnected.
Setting Directory Sharing (Only on the AQ6370D/AQ6373B/AQ6375B)
24.
Press the
FOLDER SHARING
soft key. A directory sharing setup menu appears.
25.
Press the
READ ONLY
soft key. The user area directory of the AQ6370D/
AQ6373B/AQ6375B is shared (read only).
Disables directory sharing
Enables directory sharing
• Disabling Directory Sharing
26.
Press the
DISABLE
soft key. The sharing of the user area directory is disabled.
Explanation
TCP/IP Settings
It is necessary to set up the IP address for correct use of the instrument.
If a DHCP server is provided on the network to which this instrument is connected, the
IP address given to the instrument is automatically set. Thus, set the item IP ADDRESS
SETTING under SYSTEM <NETWORK SETTING><TCP/IP SETTING> to “AUTO.”
Please ask your network administrator for details about network connections.
Note
• If you start the AQ6370C/AQ6370D/AQ6373/AQ6373B/AQ6375/AQ6375B when it is
connected to a network, it may take a few minutes for the start procedure to finish. (The
progress of initialization is indicated at the bottom of the screen with indications from “STEP
1/9” to “STEP 9/9.”)
• When the start procedure is finished and the measurement screen appears, it may take
a few more minutes before you can access the AQ6370C/AQ6370D/AQ6373/AQ6373B/
AQ6375/AQ6375B from a PC over the network. In addition, the DONE key of TCP/IP
settings may be unavailable for a certain time.
3.2 Setting Up Ethernet