6.2 Influence of Magnetic Way Leakage Flux
6.2.1 SGLG Servomotors
6-4
6.2
Influence of Magnetic Way Leakage Flux
The Magnetic Way has leakage flux. Particularly in locations where the leakage flux is 10 gauss
or higher, the influence of the leakage flux will be strongly felt. Consider this in the equipment
design. The following tables give the locations where the leakage flux will be 10 gauss for each
Servomotor model.
6.2.1
SGLG Servomotors
6.2.2
SGLF Servomotors
Magnetic Way
Model
SGLGM-
Location of 10-Gauss Leakage Flux
X (mm)
+Y (mm)
-Y (mm)
Z (mm)
30
25
25
5
35
40
C
30
30
5
40
40
C
-M
50
50
5
60
60
C
45
40
5
55
60
C
-M
65
60
5
75
90
100
85
5
115
Z
Z
X
+Y
-Y
Magnetic Way
Model
Location of 10-Gauss Leakage Flux
X (mm)
Y (mm)
+Z (mm)
-Z (mm)
SGLFM-20
60
35
65
5
SGLFM-35
70
45
85
5
SGLFM-50
90
50
105
5
SGLFM-1Z
120
60
135
5
SGLFM2-30
60
30
70
5
SGLFM2-45
90
50
105
5
SGLFM2-90
120
60
135
5
SGLFM2-1D
130
70
150
5
+Z
-Z
+Z
-Z
Y
X